Lancaster v. Carroll
- Decided
- April 22, 1919
- Docket
- No. 2118.
- Status
- Published
- Judges
- Willson
- Jurisdiction
- Texas
Cited 0 timesNo negative treatment found in this library
What does the opinion say?
WILLSON, C. J.
(after stating the facts as above;
[1] In view of the federal statute (U. S. Compiled Statutes, J 8631) declaring it to be unlawful for any common carrier engaged in interstate commerce “to use any locomotive engine propelled by steam power in moving interstate or foreign traffic unless the boiler of said locomotive and appurtenances thereof are in proper condition and safe to operate in the service to which the same is put,” it reasonably could not be, and is not, contended that appellants were not liable to appellee, if it .was true, as the jury found it was, that the explosion of the boiler was due to defects in the bolts or stays designed to sustain the crown sheet thereof; for, plainly, appellants were guilty of negligence if they used a locomotive equipped with such a boiler while engaged in interstate traffic as common carriers.
[2] Therefore the principal controversy at the trial was one as to whether the giving way of the crown sheet' of the boiler was proximately caused by defects for which appellants were responsible, or by a lack of sufficient water in the boiler to cover it for which said O. C. Carroll might have been responsible.
Appellants’ contentions with reference to this phase of the case were and are: (1) That there was no testimony which warranted the jury in finding that the bolts and stays of the crown sheet were “weak or insecure.” (2) That, if thére was such testimony, there was no testimony which warranted the finding that the defects in the bolts and stays were a proximate cause of the explosion. The contentions will be overruled; for, as we view the record, there [*798] was testimony to support each, of the findings.
It seems to have been accepted as a fact by both the parties tp the controversy that the giving way of the crown sheet was not due to á lack of sufficient water in the boiler if there was water enough therein to completely cover said crown sheet. The testimony was conflicting - as to whether there was that much water in the boiler or not, but we think a preponderance thereof supported appellee’s contention and the finding of the jury that there was. Therefore the case should be viewed as one in which it appeared that the explosion was not due to a lack of sufficient water in the boiler. Stokes, Hunter, and Jenkins, witnesses for appellants, testifying as experts, agreed that if that was true it (the explosion) should be attributed, to- “defects of material or broken bolts” in the boiler. The finding of ■the jury that it was due to “weak and insecure” bolts or stays, we think, was warranted by that testimony and testimony showing the locomotive to have been an old one; that, when inspected about a month before the explosion occurred, 10 of the stay bolts of the boiler were found to be broken and were then renewed; that after the explosion 13 stays and 7 bolts of the boiler were found to be broken; and that it could not be definitely determined whether same were broken before the explosion or by it. We think the jury had a right to infer from this testimony that the stays and bolts were “weak or insecure,” and that, because they were, the crown sheet gave way and caused the explosion.
[3] It is insisted that the verdict was excessive in amount. We do not find anything in the record which we think warrants us in saying so. Therefore the contention is overruled.
The judgment is affirmed.
(gz^ITor other cases see same topic and KEY-NUMBER in all Key-Numbered Digests and Indexes
Cite this
Lancaster v. Carroll, No. 2118. (Court of Appeals of Texas April 22, 1919)No reporter citation is stored for this case. This line is built from the stored case name, docket number, court and decision date.
The court’s opinion as stored in our database. This is the stored text for research. It is not legal advice; check the official source before you rely on it.